MATERIAL SAFETY DATA SHEET U.S. DEPARTMENT OF LABOR COMPLIES WITH USDL SAFETY AND HEALTH REGULATIONS, (29 CFR 1910.1200) IMPORTANT! THIS IS YOUR ONLY COPY. PLEASE DISTRIBUTE TO ALL PLANT LOCATIONS CODE #:10646 REV: 001 DATE SENT: 02/28/12 ************************************************************************** SECTION I. PRODUCT DESCRIPTION: NO. 10646 REMEDIA 4 MANUFACTURER: HILL MFG CO., INC. 1500 JONESBORO ROAD ATLANTA, GA 30315 EMERGENCY (800) 535-5053 M-F: 9-5 (404) 522-8364 PREPARED BY: RICK GLISSON DATE PREPARED: 02/10/12 ************************************************************************** SECTION II - HAZARDOUS INGREDIENTS HYDROGEN PEROXIDE Less Than 8%, CAS 7722-84-1, ACGIH (TLV): TWA=1 PPM, 1.4 MG/M3, REGULATED UNDER OSHA AIR CONTAMINANTS, ACGIH TLV CHEMICALS, IARC GROUP 3,4 SUBSTANCES, DOT HAZARDOUS MATERIALS, CANADIAN IDL 1% CONC., MA SUBSTANCE LIST E, NJ RIGHT TO KNOW HAZ SUBSTANCE LIST S, PA HAZARDOUS SUBSTANCE LIST. NO OTHER INGREDIENTS IN THIS MIXTURE ARE CONSIDERED TO BE HAZARDOUS ACCORDING TO ANY STATE OR FEDERAL REGULATIONS. ************************************************************************** SECTION III - PHYSICAL DATA SPECIFIC GRAVITY: 1.0257 VAPOR PRESSURE: Unknown PERCENTAGE OF VOLATILITY BY VOLUME: N/A VAPOR DENSITY (AIR =1): Unknown EVAPORATION RATE (ETHER =1): N/A SOLUBILITY IN WATER: Complete APPEARANCE AND ODOR: Clear colorless liquid, mild odor. PH: 7-8 ************************************************************************** SECTION IV - FIRE AND EXPLOSION DATA FLASH POINT (F): None FLAMMABLE LIMITS: N/A EXTINGUISHING MEDIA: Water only SPECIAL FIRE FIGHTING MEDIA: Wear full protective equipment; cool tanks and containers. UNUSUAL FIRE AND EXPLOSION HAZARDS: decomposes yielding oxygen that supports combustion of organic materials and can cause overpressure if confined. MATERIAL SAFETY DATA SHEET NO. 10646 REMEDIA 4 PAGE 2 SECTION V - HEALTH HAZARD DATA HMIS: HEALTH: 1 FIRE: 0 REACTIVITY: 0 THRESHOLD LIMIT VALUE (TLV): 1 ppm EFFECTS OF OVEREXPOSURE: Direct contact may be minimally irritating. Treatment is by dilution and is symptomatic and supportive. ROUTES OF ENTRY AND EMERGENCY FIRST AID PROCEDURES: EYE CONTACT: Irrigate freely with running water for 15 minutes and call a physician. SKIN CONTACT: Wash off with water after removing contaminated clothing and consult a physician. INHALATION: Remove at once from exposure. If irritation of nose and throat is present, call a physician. ************************************************************************** SECTION VI - REACTIVITY DATA INSTABILITY: Stable INCOMPATIBILITY: Iron, Chromium, Nickel, Mercury, Cobalt, Lead, Manganese, Tin, Dust, Rust, Dirt, Organic compounds and caustic. DECOMPOSITION: None - water and oxygen. POLYMERIZATION: Will not occur. CONDITIONS TO AVOID: pH above 8.5, trapped or inadequately vented containers, high temperatures. ************************************************************************** SECTION VII - SPILL OR LEAK PROCEDURES SPILL, LEAK OR RELEASE: Dilute with a large volume of water to approved chemical sewer to wastewater treatment system. Any combustible material exposed to products containing hydrogen peroxide should be rinsed with large volumes of water. WASTE DISPOSAL: Dispose of in accordance with federal, state and local regulations. If approved, may be drained to sewer, to waste treatment plant, may be first drained through scrap iron pit to reduce peroxide concentration. ************************************************************************** SECTION VIII - SPECIAL PROTECTION INFORMATION RESPIRATORY PROTECTION: N/A VENTILATION: Local exhaust. SPECIAL: N/A OTHER: N/A PROTECTIVE GLOVES: Neoprene, butyl rubber, vinyl gloves. EYE PROTECTION: Chemical splash goggles and face shield. OTHER PROTECTIVE EQUIPMENT: Rubber apron and boots, face shield. MATERIAL SAFETY DATA SHEET NO. 10646 REMEDIA 4 PAGE 3 SECTION IX - SPECIAL PRECAUTIONS HANDLING AND STORAGE: Do not store with reducing agents, strong alkali or mix with combustible materials. Store only in properly vented containers. Do not plug vents. Do not store in direct sunlight. OTHER PRECAUTIONS: Never return unused product back to the original container. As with all chemicals, use with due care according to label instructions and precautions. KEEP OUT OF REACH OF CHILDREN. FOR COMMERCIAL/INDUSTRIAL USE ONLY. ************************************************************************** SECTION X - TRANSPORTATION REQUIREMENTS PROPER SHIPPING NAME: NOT D.O.T. REGULATED HAZARD CLASS: N/A ID NUMBER: N/A PKG. GROUP: N/A DOT GUIDE: N/A